10. 9 inspections before operation:
Check whether the hoses and connections are damaged and aged.
At each start, the vacuum gauge of the oil suction filter element and the return filter gauge must be checked. If the pressure gauge indicates in the red area, it means that the filter element should be cleaned or replaced.
Set the pumping volume controller to "0".
Check the connection of the additive hose.
Check that the pipeline connection is sealed and tight. The electrical circuit and motor are well insulated, without damage or leakage. The electrical box meets the requirements of the specifications, and the grounding and zero connection are intact and not loose.
The batching system should be vented first to prevent damage to the additive pump. Prepare sufficient additives.
Check whether the high-pressure joint of the delivery pipeline (nozzle system) is in place and fault-free.
Check whether the water tank is filled with water.
Check the oil level of the hydraulic oil tank.